CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | +1.20 TO 18.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +0.40 TO 17.20 DEACTUATION POINT POUNDS PER SQUARE INCH |
CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW WITH SCALE AND INTERNAL DEACTUATION POINT SCREW WITH SCALE |
CONTACT LOAD CURRENT RATING | 0.4 AMPERES RESISTIVE LOAD AND 0.2 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD AND 15.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD AND 15.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CONTACT STIMULUS RATING | 1.20 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH AND 18.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH AND 0.40 DIFFERENTIAL POINT MINIMUM POUNDS PER SQUARE INCH AND 17.20 DIFFERENTIAL POINT MAXIMUM POUNDS PER SQUARE INCH |
CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 125.0 DC AT SEA LEVEL THIRD VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL SECOND VOLTAGE |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
FREQUENCY IN HERTZ | 50.0 AND 60.0 FIRST VOLTAGE |
FREQUENCY IN HERTZ | 50.0 AND 60.0 SECOND VOLTAGE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |
MEDIA FOR WHICH DESIGNED | LIQUID |
MOUNTING METHOD | UNTHREADED HOLE |
NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
OPERATING TEMP RATING | -34.0 CELSIUS MINIMUM AND 71.0 CELSIUS MAXIMUM |
PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
PRESSURE SWITCH TYPE | DIFFERENTIAL |
TERMINAL TYPE | WIRE LEAD |
THREAD QUANTITY PER INCH | 18 ALL PRESSURE CONNECTION |
THREAD SERIES DESIGNATOR | NPT ALL PRESSURE CONNECTION |
UNTHREADED MOUNTING HOLE DIAMETER | 0.265 INCHES NOMINAL |