PRESSURE SWITCH TYPE | DIFFERENTIAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT ADJUSTABLE AND |
| ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | 1.20 TO 18.00 ACTUATION POINT POUNDS PER SQUARE INCH AND |
| 0.40 TO 17.20 DEACTUATION POINT POUNDS PER SQUARE INCH |
CONTACT ADJUSTMENT TYPE | INTERNAL ACTUATION POINT SCREW WITH SCALE AND |
| INTERNAL DEACTUATION POINT SCREW WITH SCALE |
CONTACT STIMULUS RATING | 1.20 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH AND |
| 18.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH AND |
| 0.40 DIFFERENTIAL POINT MINIMUM POUNDS PER SQUARE INCH AND |
| 17.20 DIFFERENTIAL POINT MAXIMUM POUNDS PER SQUARE INCH |
CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL FIRST VOLTAGE |
| 480.0 AC AT SEA LEVEL SECOND VOLTAGE |
| 125.0 DC AT SEA LEVEL THIRD VOLTAGE |
FREQUENCY IN HERTZ | 50.0 AND |
| 60.0 FIRST VOLTAGE |
| 50.0 AND |
| 60.0 SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 15.0 AMPERES RESISTIVE LOAD AND |
| 15.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
| 15.0 AMPERES RESISTIVE LOAD AND |
| 15.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
| 0.4 AMPERES RESISTIVE LOAD AND |
| 0.2 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
OPERATING TEMP RATING | -34.0 DEG CELSIUS MINIMUM AND |
| 71.0 DEG CELSIUS MAXIMUM |
MEDIA FOR WHICH DESIGNED | LIQUID |
PRESSURE CONNECTOR TYPE | PLAIN, THREADED INTERNAL ALL CONNECTIONS |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.265 INCHES NOMINAL |
THREAD SERIES DESIGNATOR | NPT ALL PRESSURE CONNECTION |
NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
THREAD QUANTITY PER INCH | 18 ALL PRESSURE CONNECTION |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | EXPLOSION PROOF |