CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 0.5 AMPERES RESISTIVE LOAD AND 0.5 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
CONTACT STIMULUS RATING | 2.30 DEACTUATION POINT MINIMUM GALLONS PER MINUTE AND 2.50 DEACTUATION POINT MAXIMUM GALLONS PER MINUTE |
CONTACT VOLTAGE RATING IN VOLTS | 32.0 DC AT SEA LEVEL SINGLE VOLTAGE |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |
OVERALL LENGTH | 3.281 INCHES NOMINAL |
OVERALL WIDTH | 1.781 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | LIQUID |
MOUNTING METHOD | LINE AND THREADED BUSHING |
NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED BUSHING |
NONPILE-UP CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION |
OPERATING TEMP RATING | -65.0 FAHRENHEIT MINIMUM AND 250.0 FAHRENHEIT MAXIMUM |
SPECIAL FEATURES | SHOCK PROOF |
TERMINAL TYPE | WIRE LEAD |
THREAD QUANTITY PER INCH | 14 SINGLE THREADED BUSHING |
THREAD SERIES DESIGNATOR | NPT SINGLE THREADED BUSHING |