5915-01-181-3553 FILTER,BAND PASS Index 5930-01-181-3555 SWITCH,ROTARY

National Stock Number:
5930-01-181-3554

Federal Supply Class:
5930

National Item Identification Number:
011813554

Description:
SWITCH,ROTARY

Detail:
A switch actuated by a definite angular rotation of the switch shaft about its axis. For items having rated actuation travel and pressure characteristics, see SWITCH, SENSITIVE. Excludes RELAY, ROTARY; SWITCH, STEPPING; and SWITCH, TELEPHONE (as modified).


Manufacturer Information:
3600-3339-131946COLE INSTRUMENT CORP.
44HY232447-1-4-2N81073GRAYHILL INC
722017-105869RAYTHEON COMPANY
87-1929-191812JANCO CORPORATION


Techincal Specification:
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL
28.0 DC AT SEA LEVEL
CONTACT LOAD CURRENT RATING1.0 AMPERES RESISTIVE LOAD AC AT SEA LEVEL
2.0 AMPERES RESISTIVE LOAD AND
0.5 AMPERES INDUCTIVE LOAD DC AT SEA LEVEL
TERMINAL TYPETAB, SOLDER LUG
SWITCH ACTUATOR INDEXING POSITION QUANTITY2 SINGLE ACTUATOR
STYLE DESIGNATORTAP, CIRCULAR, BUSHING MOUNT
OVERALL LENGTH1.920 INCHES NOMINAL
OVERALL DIAMETER1.320 INCHES MAXIMUM
INDIVIDUAL SECTION QUANTITY1
SWITCH CONTACT BASIC DESIGNNONPILE-UP SYMMETRICAL
ROTOR THROUGH CONNECTION QUANTITY4 SINGLE SECTION
POLE QUANTITY4 SINGLE SECTION FRONT
THROW QUANTITY2 SINGLE SECTION REAR
CONTACT SWITCHING ACTIONBREAKS BEFORE MAKES SINGLE SECTION REAR
SWITCH ACTUATOR POSITIONING INCREMENT30.0 DEGREES SINGLE ACTUATOR
SWITCH ACTUATOR STOP DEVICE TYPEFIXED STOP-BREAKOFF TAB SINGLE ACTUATOR
SHAFT TYPEROUND, FLATTED SINGLE ACTUATOR
FIRST FLAT LENGTH0.440 INCHES NOMINAL SINGLE ACTUATOR
FLAT HEIGHT0.211 INCHES MINIMUM AND
0.221 INCHES MAXIMUM SINGLE ACTUATOR
SHAFT DIAMETER0.248 INCHES MINIMUM AND
0.251 INCHES MAXIMUM SINGLE ACTUATOR
SHAFT LENGTH0.880 INCHES NOMINAL SINGLE ACTUATOR
MOUNTING METHODTHREADED BUSHING SINGLE MOUNTING FACILITY
THREAD SERIES DESIGNATORUNEF SINGLE MOUNTING FACILITY
NOMINAL THREAD SIZE0.375 INCHES SINGLE MOUNTING FACILITY
THREAD CLASS2A SINGLE MOUNTING FACILITY
THREAD LENGTH0.375 INCHES NOMINAL SINGLE MOUNTING FACILITY
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONEXPLOSION PROOF


Click here to Register for Free 30-day Trial