CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE |
CONTACT ACTION STIMULUS | DECREASE |
CONTACT ADJUSTMENT RANGE | +10.00 TO 230.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +11.00 TO 250.00 DEACTUATION POINT POUNDS PER SQUARE INCH |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SERRATED NUT AND EXTERNAL DEACTUATION POINT SERRATED NUT |
CONTACT LOAD CURRENT RATING | 10.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE |
CONTACT LOAD CURRENT RATING | 3.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 125.0 AC AT SEA LEVEL THIRD VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SECOND VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 480.0 AC AT SEA LEVEL FIRST VOLTAGE |
CUBIC MEASURE | 864.000 CUBIC INCHES |
FREQUENCY IN HERTZ | 60.0 FIRST VOLTAGE |
FREQUENCY IN HERTZ | 60.0 SECOND VOLTAGE |
FREQUENCY IN HERTZ | 60.0 THIRD VOLTAGE |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 1.436 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.436 INCHES NOMINAL |
OVERALL HEIGHT | 4.312 INCHES NOMINAL |
OVERALL LENGTH | 2.905 INCHES NOMINAL |
OVERALL WIDTH | 1.937 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS |
MOUNTING FACILITY PATTERN | TWO POSITION DIAGONAL |
MOUNTING METHOD | BASE AND THREADED HOLE |
NOMINAL THREAD SIZE | 0.250 INCHES SINGLE PRESSURE CONNECTION |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
PRESSURE SWITCH TYPE | GAGE |
SPECIAL FEATURES | USED ON 210 FT U. S. COAST GUARD VESSELS |
STYLE DESIGNATOR | RECTANGULAR |
TERMINAL TYPE | TAB W/SCREW |
THREAD SERIES DESIGNATOR | NPT SINGLE PRESSURE CONNECTION |
THREAD QUANTITY PER INCH | 24 SINGLE PRESSURE CONNECTION |