STYLE DESIGNATOR | DISC W/FLANGE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | 175.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND |
| 165.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CONTACT VOLTAGE RATING IN VOLTS | 30.0 AC AT SEA LEVEL FIRST VOLTAGE |
| 125.0 AC AT SEA LEVEL SECOND VOLTAGE |
| 250.0 AC AT SEA LEVEL THIRD VOLTAGE |
| 30.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CONTACT LOAD CURRENT RATING | 14.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| 12.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| 6.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| 14.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND |
| 450.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS OR |
| LIQUID |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | TAB, SOLDER LUG |
MOUNTING METHOD | BRACKET AND |
| UNTHREADED HOLE |
UNTHREADED MOUNTING HOLE DIAMETER | 0.094 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.469 INCHES NOMINAL |
FEATURES PROVIDED | AUTOMATIC RESET |
SPECIFICATION/STANDARD DATA | 80063-A318560 GOVERNMENT SPECIFICATION |