CONTACT VOLTAGE RATING IN VOLTS | 440.0 HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| 110.0 LOWEST AC VOLTAGE RATING AT SEA LEVEL |
| 250.0 HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
| 115.0 LOWEST DC VOLTAGE RATING AT SEA LEVEL |
CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD HIGHEST AC VOLTAGE RATING AT SEA LEVEL |
| 4.0 AMPERES INDUCTIVE LOAD LOWEST AC VOLTAGE RATING AT SEA LEVEL |
| 200.0 MILLIAMPERES INDUCTIVE LOAD HIGHEST DC VOLTAGE RATING AT SEA LEVEL |
| 1.5 AMPERES INDUCTIVE LOAD LOWEST DC VOLTAGE RATING AT SEA LEVEL |
TERMINAL TYPE | SCREW |
SWITCH ACTUATOR INDEXING POSITION QUANTITY | 3 SINGLE ACTUATOR |
STYLE DESIGNATOR | IN-LINE, CAM ACTUATED |
OVERALL LENGTH | 9.900 INCHES NOMINAL |
OVERALL HEIGHT | 5.250 INCHES NOMINAL |
OVERALL WIDTH | 5.000 INCHES NOMINAL |
INDIVIDUAL SECTION QUANTITY | 6 |
SWITCH CONTACT BASIC DESIGN | NONPILE-UP NONSYMMETRICAL |
SWITCH ACTUATOR MOMENTARY POSITION | CLOCKWISE AND |
| COUNTERCLOCKWISE SINGLE ACTUATOR |
MOUNTING METHOD | UNTHREADED HOLE SINGLE MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.406 INCHES NOMINAL SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR SINGLE MOUNTING FACILITY |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 4.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 0.800 INCHES NOMINAL SINGLE MOUNTING FACILITY |
FEATURES PROVIDED | ACTUATOR KNOB AND |
| LEGEND PLATE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | SHOCK PROOF AND |
| WATERTIGHT |
SPECIAL FEATURES | LEGEND CORRESPONDS WITH POSITIONS AND READS FROM RIGHT TO LEFT AS FOLLOWS; PAYOUT,OFF,INHAUL |