BODY DIAMETER | 0.300 INCHES MAXIMUM |
BODY LENGTH | 0.700 INCHES MAXIMUM |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT LOAD CURRENT RATING | 1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT STIMULUS RATING | 70.00 ACTUATION POINT NOMINAL DEGREES CELSIUS |
CONTACT VOLTAGE RATING IN VOLTS | 100.0 DC AT SEA LEVEL SECOND VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.700 INCHES NOMINAL |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
OVERALL DIAMETER | 0.300 INCHES MAXIMUM |
OVERALL LENGTH | 1.590 INCHES NOMINAL |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
MOUNTING METHOD | BRACKET AND THREADED STUD |
NOMINAL THREAD SIZE | 0.112 INCHES ALL THREADED STUD |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
STYLE DESIGNATOR | CYLINDRICAL |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | WIRE LEAD |
THREAD CLASS | 2A ALL THREADED STUD |
THREAD SERIES DESIGNATOR | UNC ALL THREADED STUD |
THREAD QUANTITY PER INCH | 40 ALL THREADED STUD |