5930-01-312-5600 SWITCH,THERMOSTATIC Index 5930-01-312-5602 SWITCH,FLOW

National Stock Number:
5930-01-312-5601

Federal Supply Class:
5930

National Item Identification Number:
013125601

Description:
SWITCH,THERMOSTATIC

Detail:
A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).


Manufacturer Information:
588498853711NAVAL SEA SYSTEMS COMMAND
5884988-106KW9LUCENT TECHNOLOGIES INC DBA FEDERAL MARKETING GROUP
5884988-153711NAVAL SEA SYSTEMS COMMAND
5884988-164959AMERICAN TELEPHONE AND TELEGRAPH CO
5884988-192663AT AND T CO ADVANCED TECHNOLOGY SYSTEMS
5884988-299414TYLER REFRIGERATION CORP
M24236/20-CFDA81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
STYLE DESIGNATORDISC
OVERALL LENGTH1.040 INCHES MAXIMUM
OVERALL HEIGHT0.360 INCHES MAXIMUM
BODY DIAMETER0.660 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CONTACT ACTION STIMULUSINCREASE
CONTACT ADJUSTABILITYACTUATION POINT NOT ADJUSTABLE AND
DEACTUATION POINT NOT ADJUSTABLE
CONTACT STIMULUS RATING130.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND
125.00 DEACTUATION POINT MINIMUM DEGREES FAHRENHEIT AND
128.00 DEACTUATION POINT MAXIMUM DEGREES FAHRENHEIT
CONTACT VOLTAGE RATING IN VOLTS115.0 AC AT SEA LEVEL FIRST VOLTAGE
28.0 DC AT SEA LEVEL SECOND VOLTAGE
FREQUENCY IN HERTZ60.0 FIRST VOLTAGE
CONTACT LOAD CURRENT RATING2.0 AMPERES RESISTIVE LOAD AND
1.5 AMPERES INDUCTIVE LOAD AND
0.5 AMPERES LAMP LOAD FIRST VOLTAGE
2.0 AMPERES RESISTIVE LOAD AND
1.0 AMPERES INDUCTIVE LOAD AND
1.0 AMPERES LAMP LOAD SECOND VOLTAGE
OPERATING TEMP RATING-10.0 DEG FAHRENHEIT MINIMUM AND
250.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNEDGAS OR
LIQUID
TEMP SENSING ELEMENT TYPEINTERNAL SENSOR
TERMINAL TYPEWIRE LEAD
MOUNTING METHODBRACKET AND
SLOT
MOUNTING SLOT WIDTH0.140 INCHES NOMINAL
MOUNTING FACILITY PATTERNTWO POSITION IN-LINE
DISTANCE BETWEEN MOUNTING FACILITY CENTERS0.937 INCHES MINIMUM AND
0.999 INCHES MAXIMUM
FEATURES PROVIDEDHERMETICALLY SEALED CASE
SPECIAL FEATURESTERMINALS 5.500 IN. LG
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTIONVIBRATION RESISTANT


Click here to Register for Free 30-day Trial