STYLE DESIGNATOR | CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 5.281 INCHES NOMINAL |
WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
BODY DIAMETER | 0.618 INCHES MINIMUM AND |
| 0.625 INCHES MAXIMUM |
BODY LENGTH | 4.062 INCHES NOMINAL |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE |
CONTACT ADJUSTMENT RANGE | -100.00 TO 600.00 ACTUATION POINT DEGREES FAHRENHEIT |
CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SCREW |
CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL FIRST VOLTAGE |
| 240.0 AC AT SEA LEVEL SECOND VOLTAGE |
| 28.0 DC AT SEA LEVEL THIRD VOLTAGE |
| 115.0 DC AT SEA LEVEL FOURTH VOLTAGE |
CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| 2.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE |
| 2.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE |
MEDIA FOR WHICH DESIGNED | GAS OR |
| LIQUID |
TEMP SENSING ELEMENT TYPE | EXPANDING SHELL |
TERMINAL TYPE | WIRE LEAD |
MOUNTING METHOD | THREADED BUSHING |
THREAD SERIES DESIGNATOR | NPT SINGLE THREADED BUSHING |
NOMINAL THREAD SIZE | 0.500 INCHES SINGLE THREADED BUSHING |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | CORROSION RESISTANT |