CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 10.0 MILLIAMPERES RESISTIVE LOAD AND 200.0 MILLIAMPERES LAMP LOAD SINGLE VOLTAGE |
CONTACT STIMULUS RATING | 12.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH AND 10.00 DEACTUATION POINT NOMINAL POUNDS PER SQUARE INCH |
CONTACT VOLTAGE RATING IN VOLTS | 28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
OVERALL DIAMETER | 1.000 INCHES MAXIMUM |
OVERALL LENGTH | 3.100 INCHES MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
MOUNTING METHOD | LINE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
NUCLEAR HARDNESS CRITICAL FEATURE | HARDENED |
PRESSURE CONNECTOR TYPE | GROOVED, UNTHREADED EXTERNAL SINGLE CONNECTION |
PRESSURE SWITCH TYPE | GAGE |
PROOF PRESSURE | 240.00 POUNDS PER SQUARE INCH GAGE |
SENSING ELEMENT BURST PRESSURE | 360.00 POUNDS PER SQUARE INCH GAGE |
STYLE DESIGNATOR | CYLINDRICAL |
WIDTH ACROSS FLATS | 1.000 INCHES NOMINAL |
TERMINAL TYPE | CONNECTOR, RECEPTACLE |