DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 23.80 MILLIMETERS NOMINAL |
BODY DIAMETER | 18.00 MILLIMETERS NOMINAL |
CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CONTACT LOAD CURRENT RATING | 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
CONTACT STIMULUS RATING | 67.00 ACTUATION POINT MINIMUM DEGREES CELSIUS AND 73.00 ACTUATION POINT MAXIMUM DEGREES CELSIUS AND 15.00 DIFFERENTIAL POINT NOMINAL DEGREES CELSIUS |
CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL FIRST VOLTAGE |
CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SECOND VOLTAGE |
III OVERALL LENGTH | 30.40 MILLIMETERS NOMINAL |
III STYLE DESIGNATOR | DISC W/FLANGE |
MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
MOUNTING METHOD | UNTHREADED HOLE |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
OVERALL HEIGHT | 18.50 MILLIMETERS NOMINAL |
TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
TERMINAL TYPE | QUICK DISCONNECT, MALE |
UNTHREADED MOUNTING HOLE DIAMETER | 3.70 MILLIMETERS NOMINAL |