National Stock Number: 5940-00-470-2287
Federal Supply Class: 5940
National Item Identification Number: 004702287
Description: TERMINAL,STUD
Detail: A terminal, generally postlike, having an axial portion of its body designed for projecting through or into a panel, or the like, for mounting. Requires the use of tool(s) for attachment of wire. The conductor connection may be insulated from the mounting. Excludes TERMINAL, FEEDTHRU. See also TERMINAL, QUICK DISCONNECT and TERMINAL SET, QUICK DISCONNECT.
|
Manufacturer Information:
556011-052 | 28499 | CHEMLEC PRODUCTS INC | 69002-0002 | 28499 | CHEMLEC PRODUCTS INC |
|
Techincal Specification:
BASIC SHAPE STYLE | NONTUBULAR, HEX | TERMINAL LENGTH | 0.136 INCHES | WIDTH ACROSS FLATS | 0.156 INCHES | OVERALL HEIGHT | 0.547 INCHES | CONDUCTOR ACCOMMODATION TYPE | DOUBLE TURRET SINGLE END | LARGEST DIAMETER | 0.066 INCHES SINGLE END | TURRET MINOR DIAMETER | 0.045 INCHES SINGLE END | MOUNTING METHOD STYLE | TAPPED HOLE | THREAD LENGTH | 0.181 INCHES | MOUNTING THREAD SERIES | UNC | MOUNTING THREAD DIAMETER | 0.112 INCHES | ELECTRICAL INSULATION FEATURE | STANDOFF INSULATION | IDENTIFICATION CODE COLOR | OLIVE DRAB | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE INSULATION | | COPPER ALLOY OVERALL EXCEPT INSULATION | SURFACE TREATMENT | ANODIZE CONDUCTOR ACCOMMODATION SINGLE LAYER | | CADMIUM MOUNTING FACILITY SINGLE LAYER | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | QQ-P-416,TY2,CL 3 FED SPEC SINGLE TREATMENT RESPONSE MOUNTING FACILITY SINGLE LAYER | DRY FLASHOVER VOLTAGE RATING IN VOLTS | 7000.0 | THE MANUFACTURERS DATA | | MANUFACTURERS CODE | 28499 | DESIGN CONTROL REFERENCE | 69002-0002 |
|
|