5935-00-062-1214 CONNECTOR BODY,RECEPTACLE,ELECTR Index 5950-00-062-1216 REACTOR

National Stock Number:
5945-00-062-1215

Federal Supply Class:
5945

National Item Identification Number:
000621215

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
3346-9901399699DRI RELAYS INC.
9330-402796906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS24149-A196906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND
28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND
10.0 AMPERES DC RESISTIVE LOAD
10.0 AMPERES AC AND
10.0 AMPERES DC INDUCTIVE LOAD
2.0 AMPERES AC AND
2.0 AMPERES DC LAMP LOAD
6.0 AMPERES AC AND
6.0 AMPERES DC MOTOR LOAD
ARC QUENCHING METHODAIR
COIL QUANTITY1
WINDING QUANTITY1
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
FREQUENCY IN HERTZ400.0 NOMINAL
TERMINAL TYPE AND QUANTITY8 SCREW ALL FUNCTIONS
TIME DELAY0.02 SECONDS MAXIMUM FIXED OPERATE TIME
0.05 SECONDS MAXIMUM FIXED RELEASE TIME
DUTY TYPECONTINUOUS
ENVIRONMENTAL PROTECTIONHERMETIC
OVERALL LENGTH2.500 INCHES MAXIMUM
OVERALL WIDTH1.625 INCHES MAXIMUM
OVERALL HEIGHT2.600 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE FIRST MOUNTING FACILITY
6 UNTHREADED HOLE SECOND MOUNTING FACILITY
MOUNTING FACILITY PATTERNRECTANGULAR FIRST MOUNTING FACILITY
RECTANGULAR SECOND MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH2.125 INCHES NOMINAL FIRST MOUNTING FACILITY
2.125 INCHES NOMINAL SECOND MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.000 INCHES NOMINAL FIRST MOUNTING FACILITY
1.000 INCHES NOMINAL SECOND MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER0.173 INCHES NOMINAL FIRST MOUNTING FACILITY
0.173 INCHES NOMINAL SECOND MOUNTING FACILITY
FEATURES PROVIDEDCOIL VOLTAGE SUPPRESSION
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA96906-MS24149 GOVERNMENT STANDARD
PURPOSE FOR WHICH DESIGNEDGENERAL
CUBIC MEASURE10.562 CUBIC INCHES
FRAGILITY FACTORMODERATELY RUGGED
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CASE MATERIALMETAL
SPEC/STD CONTROLLING DATA
MANUFACTURERS CODE81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCEMIL-PRF-6106
MANUFACTURERS CODE96906
DEFINITIVE GOVERNMENT SPEC/STD REFERENCEMS24149-A1