| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY | 
| COIL QUANTITY | 1 | 
| WINDING QUANTITY | 1 | 
| WINDING DC RESISTANCE RATING | 550.0 OHMS NOMINAL SINGLE WINDING | 
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING | 
| NOMINAL OPERATING CURRENT RATING AND TYPE | 50.0 AMPERES DC SINGLE WINDING | 
| TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS | 
| TIME DELAY | 0.0050 SECONDS NOMINAL FIXED OPERATE TIME | 
 | 0.005 SECONDS NOMINAL FIXED RELEASE TIME | 
| DUTY TYPE | CONTINUOUS | 
| ENVIRONMENTAL PROTECTION | HERMETIC | 
| OVERALL LENGTH | 2.170 INCHES NOMINAL | 
| OVERALL WIDTH | 0.790 INCHES NOMINAL | 
| OVERALL HEIGHT | 0.350 INCHES NOMINAL | 
| MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY | 
| MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY | 
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.412 INCHES NOMINAL SINGLE MOUNTING FACILITY | 
| THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY | 
| NOMINAL THREAD SIZE | 0.112 INCHES SINGLE MOUNTING FACILITY | 
| THREAD CLASS | 2A SINGLE MOUNTING FACILITY | 
| SPECIAL FEATURES | ELECTRICAL AND MECHANICAL SPECIFICATIONS AND DESIGN APPROVAL PER REEVES DWG NO. 178879 | 
| FSC APPLICATION DATA | RELEAY ARMATURE EXCEPT ENGINE |