5950-00-235-8950 TRANSFORMER,AUDIO FREQUENCY Index 5945-00-235-8953 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-00-235-8952

Federal Supply Class:
5945

National Item Identification Number:
002358952

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
M5757/37-00981349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-5757/3781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
WINDING QUANTITY1
SPECIFICATION/STANDARD DATA81349-MIL-R-5757/37 GOVERNMENT SPECIFICATION
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
TERMINAL TYPE AND QUANTITY8 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-5757 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CASE MATERIALMETAL
COIL QUANTITY1
CUBIC MEASURE0.060 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL HEIGHT0.320 INCHES MAXIMUM
OVERALL LENGTH0.610 INCHES MAXIMUM
OVERALL WIDTH0.310 INCHES MAXIMUM
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE125.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL SINGLE MOUNTING FACILITY
PURPOSE FOR WHICH DESIGNEDGENERAL
WINDING DC RESISTANCE RATING1.2 KILOHMS MINIMUM SINGLE WINDING AND 1.5 KILOHMS MAXIMUM SINGLE WINDING


Click here to Register for Free 30-day Trial