DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | NITROGEN |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | SALT SPRAY RESISTANT |
NOMINAL OPERATING CURRENT RATING AND TYPE | 35.0 MILLIAMPERES DC SINGLE WINDING |
NOMINAL THREAD SIZE | 0.164 INCHES SINGLE MOUNTING FACILITY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 39.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 3.437 INCHES NOMINAL |
OVERALL LENGTH | 4.687 INCHES NOMINAL |
OVERALL WIDTH | 2.187 INCHES NOMINAL |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SINGLE MOUNTING FACILITY |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
SPECIAL FEATURES | RESISTANT TO SALT WATER SPRAY |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TIME DELAY | 0.10 SECONDS NOMINAL FIXED OPERATE TIME |
WINDING DC RESISTANCE RATING | 300.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |