DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | INERT GAS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.375 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
NOMINAL OPERATING CURRENT RATING AND TYPE | 1.6 MILLIAMPERES DC ALL WINDINGS |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OVERALL HEIGHT | 3.120 INCHES NOMINAL |
OVERALL LENGTH | 1.500 INCHES NOMINAL |
OVERALL WIDTH | 1.500 INCHES NOMINAL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 24.0 DC |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
WINDING DC RESISTANCE RATING | 1.0 OHMS MINIMUM ALL WINDINGS AND 1.0 KILOHMS MAXIMUM ALL WINDINGS |
WINDING QUANTITY | 2 |
TERMINAL TYPE AND QUANTITY | 5 PIN ALL FUNCTIONS |