CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.488 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND WATER RESISTANT |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC AND 500.0 MILLIAMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 50.0 AC AND 50.0 DC |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1A AND 2B AND 2C |
MOUNTING FACILITY PATTERN | DIAGONAL SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 55.0 MILLIAMPERES DC SINGLE WINDING |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 22.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 1.390 INCHES MAXIMUM |
OVERALL LENGTH | 4.594 INCHES MAXIMUM |
OVERALL WIDTH | 1.438 INCHES MAXIMUM |
TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
WINDING DC RESISTANCE RATING | 235.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |