CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.787 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.149 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
DUTY TYPE | CONTINUOUS |
FREQUENCY IN HERTZ | 60.0 NOMINAL |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC RESISTIVE LOAD |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1C |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 3.3 AMPERES AC ALL WINDINGS |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS ALL WINDINGS |
OVERALL HEIGHT | 2.400 INCHES NOMINAL |
OVERALL LENGTH | 3.310 INCHES NOMINAL |
OVERALL WIDTH | 1.750 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 7 PIN ALL FUNCTIONS |
UNTHREADED MOUNTING HOLE DIAMETER | 0.149 INCHES NOMINAL SINGLE MOUNTING FACILITY |
WINDING QUANTITY | 2 |