ARC QUENCHING METHOD | INERT GAS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.181 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 24.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES DC RESISTIVE LOAD |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 2.430 INCHES NOMINAL |
OVERALL LENGTH | 1.650 INCHES NOMINAL |
OVERALL WIDTH | 1.430 INCHES NOMINAL |
TERMINAL TYPE AND QUANTITY | 11 PIN ALL FUNCTIONS |
WINDING DC RESISTANCE RATING | 170.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |