| NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 24.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 800.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 1.3 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 17.5 AMPERES DC SINGLE WINDING |
| DUTY TYPE | INTERMITTENT |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 10.563 INCHES NOMINAL |
| OVERALL WIDTH | 3.625 INCHES NOMINAL |
| OVERALL HEIGHT | 5.375 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.344 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| SPECIAL FEATURES | MTG FACILITY 2 ON TOP 2-7/8 IN. C TO C,1 ON BOTTOM VERTICAL CENTER LINE 9-9/16 IN. FROM HORIZONTAL CENTER LINE OF TOP MTG HOLES |