NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND |
| 3.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 6.5 KILOHMS NOMINAL SINGLE WINDING |
NOMINAL OPERATING CURRENT RATING AND TYPE | 10.0 MILLIAMPERES DC SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC AND |
| SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
OVERALL LENGTH | 1.643 INCHES MAXIMUM |
OVERALL WIDTH | 1.455 INCHES MAXIMUM |
OVERALL HEIGHT | 2.610 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.938 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.187 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |
CUBIC MEASURE | 6.239 CUBIC INCHES |
CONTACT MATERIAL | SILVER |
CONTACT SURFACE TREATMENT | GOLD |
CASE MATERIAL | METAL |
PRECIOUS MATERIAL | GOLD AND |
| SILVER |
PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER AND |
| CONTACT SURFACES GOLD |