PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2A |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND |
| 5.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 280.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
NOMINAL OPERATING CURRENT RATING AND TYPE | 40.0 MILLIAMPERES DC SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND |
| WATERTIGHT |
OVERALL LENGTH | 2.000 INCHES NOMINAL |
OVERALL WIDTH | 1.250 INCHES NOMINAL |
OVERALL HEIGHT | 1.930 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
UNTHREADED MOUNTING HOLE DIAMETER | 0.144 INCHES NOMINAL SINGLE MOUNTING FACILITY |