NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND |
| 2.0 AMPERES DC RESISTIVE LOAD |
| 1.0 AMPERES DC INDUCTIVE LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 540.0 OHMS MINIMUM AND |
| 660.0 OHMS MAXIMUM SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
NOMINAL OPERATING CURRENT RATING AND TYPE | 9.2 MILLIAMPERES DC SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
TIME DELAY | 0.005 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.004 SECONDS MAXIMUM FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 0.790 INCHES MINIMUM AND |
| 0.800 INCHES MAXIMUM |
OVERALL WIDTH | 0.390 INCHES MINIMUM AND |
| 0.400 INCHES MAXIMUM |
OVERALL HEIGHT | 0.890 INCHES MINIMUM AND |
| 0.900 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
CUBIC MEASURE | 0.281 CUBIC INCHES |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |