PILE-UP MAIN CONTACT FORM ARRANGEMENT | 2C |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 30.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND |
| 2.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
NOMINAL OPERATING CURRENT RATING AND TYPE | 50.0 MILLIAMPERES DC SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
OVERALL LENGTH | 1.210 INCHES NOMINAL |
OVERALL WIDTH | 1.090 INCHES NOMINAL |
OVERALL HEIGHT | 0.400 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.086 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2B SINGLE MOUNTING FACILITY |