NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC INDUCTIVE LOAD |
ARC QUENCHING METHOD | INERT GAS |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.0500 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.0500 SECONDS MAXIMUM FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
OVERALL LENGTH | 2.728 INCHES MAXIMUM |
OVERALL WIDTH | 1.438 INCHES NOMINAL |
OVERALL HEIGHT | 1.648 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.938 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.188 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD LENGTH | 0.343 INCHES MINIMUM AND |
| 0.406 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
THE MANUFACTURERS DATA | |
MANUFACTURERS CODE | 10001 |
DESIGN CONTROL REFERENCE | 2498898-001 |