NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 32.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC AND |
| 2.0 AMPERES DC RESISTIVE LOAD |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
ENERGIZING ELEMENT POWER RATING | 6.0 WATTS |
FREQUENCY IN HERTZ | 400.0 NOMINAL |
TERMINAL TYPE AND QUANTITY | 6 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.05 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.10 SECONDS MAXIMUM FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC AND |
| SHOCK RESISTANT AND |
| VIBRATION RESISTANT |
OVERALL LENGTH | 1.750 INCHES NOMINAL |
OVERALL WIDTH | 1.250 INCHES NOMINAL |
OVERALL HEIGHT | 2.880 INCHES NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED STUD SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.750 INCHES NOMINAL SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND SINGLE MOUNTING FACILITY |