DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
COIL QUANTITY | 2 |
ENVIRONMENTAL PROTECTION | SHOCK RESISTANT AND VIBRATION RESISTANT AND HERMETIC |
FEATURES PROVIDED | POLARIZED AND LATCHING CONTACTS |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC INDUCTIVE LOAD AND 8.0 AMPERES DC INDUCTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
III CUBIC MEASURE | 0.544 CUBIC INCHES |
PROPRIETARY CHARACTERISTICS | PACS |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.140 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 50.0 MILLIAMPERES DC SINGLE WINDING |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
OVERALL HEIGHT | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
OVERALL LENGTH | 1.698 INCHES MINIMUM AND 1.718 INCHES MAXIMUM |
OVERALL WIDTH | 0.505 INCHES MINIMUM AND 0.525 INCHES MAXIMUM |
PURPOSE FOR WHICH DESIGNED | GENERAL |
WINDING DC RESISTANCE RATING | 540.0 OHMS MINIMUM ALL WINDINGS AND 660.0 OHMS MAXIMUM ALL WINDINGS |
WINDING QUANTITY | 2 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |