| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| WINDING DC RESISTANCE RATING | 120.0 OHMS NOMINAL SINGLE WINDING |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| NOMINAL OPERATING CURRENT RATING AND TYPE | 100.0 MILLIAMPERES DC SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 1.375 INCHES MINIMUM AND |
| 1.625 INCHES MAXIMUM |
| OVERALL WIDTH | 1.250 INCHES MINIMUM AND |
| 1.500 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.500 INCHES NOMINAL |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| SPECIAL FEATURES | OPERATING TEMPERATURE RANGE MINUS 46 DEG C TO PLUS 75 DEG C |
| CASE MATERIAL | METAL |