| NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 600.0 AC AND |
| 250.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC AND |
| 40.0 AMPERES DC RESISTIVE LOAD |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | HERMETIC |
| OVERALL LENGTH | 3.750 INCHES NOMINAL |
| OVERALL WIDTH | 3.250 INCHES NOMINAL |
| OVERALL HEIGHT | 4.500 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE FIRST MOUNTING FACILITY |
| 2 UNTHREADED HOLE SECOND MOUNTING FACILITY |
| 4 UNTHREADED HOLE THIRD MOUNTING FACILITY |
| MOUNTING FACILITY PATTERN | IN-LINE FIRST MOUNTING FACILITY |
| DIAGONAL SECOND MOUNTING FACILITY |
| RECTANGULAR THIRD MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.750 INCHES NOMINAL FIRST MOUNTING FACILITY |
| 2.284 INCHES NOMINAL SECOND MOUNTING FACILITY |
| 3.125 INCHES NOMINAL THIRD MOUNTING FACILITY |
| CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.772 INCHES NOMINAL SECOND MOUNTING FACILITY |
| 1.937 INCHES NOMINAL THIRD MOUNTING FACILITY |
| UNTHREADED MOUNTING HOLE DIAMETER | 0.188 INCHES NOMINAL SECOND MOUNTING FACILITY |
| 0.188 INCHES NOMINAL THIRD MOUNTING FACILITY |
| MOUNTING SLOT WIDTH | 0.250 INCHES NOMINAL FIRST MOUNTING FACILITY |