5910-01-124-4219 CAPACITOR,FIXED,ELECTROLYTIC Index 5210-01-124-4221 SCALE

National Stock Number:
5945-01-124-4220

Federal Supply Class:
5945

National Item Identification Number:
011244220

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
J411-12PM11532TELEDYNE DEFENSE ELECTRONICS, LLC
M39016/07-020P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/07-028P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/7-008M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/7-028P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M5757-38-00781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/781349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
COIL QUANTITY1
CRITICALITY CODE JUSTIFICATIONFEAT
DUTY TYPECONTINUOUS
ENVIRONMENTAL PROTECTIONHERMETIC
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE1.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE100.0 MILLIAMPERES DC LAMP LOAD
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
OVERALL DIAMETER0.370 INCHES MAXIMUM
OVERALL LENGTH0.280 INCHES MAXIMUM
SPECIAL FEATURESFAILURE RATE LEVEL 0.1 PERCENT
SPECIFICATION/STANDARD DATA81349-MIL-R-39016/7 GOVERNMENT SPECIFICATION
TERMINAL TYPE AND QUANTITY5 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.002 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
WINDING DC RESISTANCE RATING500.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1


Click here to Register for Free 30-day Trial