5330-01-137-0876 RETAINER,PACKING Index 5935-01-137-0878 CONNECTOR,RECEPTACLE,ELECTRICAL

National Stock Number:
5945-01-137-0877

Federal Supply Class:
5945

National Item Identification Number:
011370877

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
M39016-18-004P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/1881349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
COIL QUANTITY1
ENVIRONMENTAL PROTECTIONHERMETIC
FEATURES PROVIDEDPOLARIZED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE200.0 MILLIAMPERES DC INDUCTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE1.0 AMPERES DC RESISTIVE LOAD
OVERALL HEIGHT0.230 INCHES MAXIMUM
OVERALL LENGTH0.370 INCHES MAXIMUM
OVERALL WIDTH0.370 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
SPECIAL FEATURESFAILURE RATED AT 0.1 PER CENT PER 10000 OPERATIONS
WINDING DC RESISTANCE RATING309.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY8 WIRE LEAD ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-39016/18 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.002 SECONDS MAXIMUM FIXED OPERATE TIME
TIME DELAY0.004 SECONDS MAXIMUM FIXED RELEASE TIME


Click here to Register for Free 30-day Trial