DUTY TYPE | CONTINUOUS |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 4.562 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | SHOCK PROOF AND VIBRATION PROOF |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 300.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
OVERALL HEIGHT | 2.970 INCHES MAXIMUM |
OVERALL LENGTH | 5.190 INCHES MAXIMUM |
OVERALL WIDTH | 2.560 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 400.0 MILLIAMPERES DC SINGLE WINDING |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-6106/34 GOVERNMENT SPECIFICATION |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 7 THREADED STUD ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
TIME DELAY | 0.05 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
UNTHREADED MOUNTING HOLE DIAMETER | 0.266 INCHES MINIMUM SINGLE MOUNTING FACILITY |