NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND |
| 10.0 AMPERES DC RESISTIVE LOAD |
| 8.0 AMPERES AC AND |
| 8.0 AMPERES DC INDUCTIVE LOAD |
| 2.0 AMPERES AC AND |
| 2.0 AMPERES DC LAMP LOAD |
| 4.0 AMPERES AC AND |
| 4.0 AMPERES DC MOTOR LOAD |
ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
WINDING QUANTITY | 1 |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS AND |
| 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
FREQUENCY IN HERTZ | 400.0 NOMINAL |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | DUSTPROOF |
OVERALL LENGTH | 1.718 INCHES MAXIMUM |
OVERALL WIDTH | 0.515 INCHES NOMINAL |
OVERALL HEIGHT | 1.125 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.421 INCHES NOMINAL SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
PURPOSE FOR WHICH DESIGNED | GENERAL |
CUBIC MEASURE | 0.995 CUBIC INCHES |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CASE MATERIAL | METAL |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 49956 |
MFR SOURCE CONTROLLING REFERENCE | 929046-2 |