ARC QUENCHING METHOD | AIR |
COIL QUANTITY | 1 |
CUBIC MEASURE | 1.517 CUBIC INCHES |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | DUSTPROOF |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 30.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 AMPERES AC AND 3.0 AMPERES DC RESISTIVE LOAD |
MATERIAL | PLASTIC CASE |
MATERIAL | SILVER CONTACT |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL FIRST MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SECOND MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.099 INCHES SECOND MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 1.593 INCHES MAXIMUM |
OVERALL LENGTH | 1.109 INCHES MAXIMUM |
OVERALL WIDTH | 0.859 INCHES MAXIMUM |
PRECIOUS MATERIAL AND LOCATION | CONTACTS SILVER |
PRECIOUS MATERIAL | SILVER |
PURPOSE FOR WHICH DESIGNED | GENERAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 14 TAB, SOLDER LUG ALL FUNCTIONS |
THREAD CLASS | 2A SECOND MOUNTING FACILITY |
THREAD LENGTH | 0.312 INCHES NOMINAL SECOND MOUNTING FACILITY |
THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 48 SECOND MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
WINDING DC RESISTANCE RATING | 3.3 KILOHMS MINIMUM AND 4.5 KILOHMS MAXIMUM SINGLE WINDING |
WINDING QUANTITY | 1 |