5310-01-194-8593 WASHER,FLAT Index 5355-01-194-8596 KNOB

National Stock Number:
5945-01-194-8594

Federal Supply Class:
5945

National Item Identification Number:
011948594

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
7906324-0190536LOCKHEED MARTIN CORP
M39016/14-004L81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/14-004M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/1481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/1481349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
COIL QUANTITY1
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE500.0 MILLIAMPERES AC AND 500.0 MILLIAMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT0.531 INCHES MAXIMUM
OVERALL LENGTH0.610 INCHES MAXIMUM
OVERALL WIDTH0.610 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
SPECIFICATION/STANDARD DATA81349--39016/14-004 GOVERNMENT SPECIFICATION
WINDING DC RESISTANCE RATING720.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY14 PIN ALL FUNCTIONS
TEST DATA DOCUMENT81349--39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.01 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME


Click here to Register for Free 30-day Trial