4730-01-216-8453 PLUG,VALVE,INSERT Index 5945-01-216-8455 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-01-216-8454

Federal Supply Class:
5945

National Item Identification Number:
012168454

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
M39016/6-124L81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/6-124M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/6-124P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND
28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE300.0 MILLIAMPERES AC AND
2.0 AMPERES DC RESISTIVE LOAD
750.0 MILLIAMPERES DC INDUCTIVE LOAD
160.0 MILLIAMPERES DC LAMP LOAD
ARC QUENCHING METHODAIR
COIL QUANTITY1
WINDING QUANTITY1
WINDING DC RESISTANCE RATING40.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY8 WIRE LEAD ALL FUNCTIONS
TIME DELAY0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
DUTY TYPECONTINUOUS
ENVIRONMENTAL PROTECTIONHERMETIC
OVERALL LENGTH0.810 INCHES MAXIMUM
OVERALL WIDTH0.410 INCHES MAXIMUM
OVERALL HEIGHT0.410 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY1 TERMINAL SINGLE MOUNTING FACILITY
FEATURES PROVIDEDPOLARIZED
SPECIAL FEATURESFAILURE RATE LEVEL 0.1 PERCENT
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-R-39016/6 GOVERNMENT SPECIFICATION
CRITICALITY CODE JUSTIFICATIONFEAT
PURPOSE FOR WHICH DESIGNEDGENERAL
CUBIC MEASURE0.136 CUBIC INCHES
FRAGILITY FACTORMODERATELY RUGGED
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CASE MATERIALMETAL
SPEC/STD CONTROLLING DATA
MANUFACTURERS CODE81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCEMIL-PRF-39016/6
DEFINITIVE GOVERNMENT SPEC/STD REFERENCEM39016/6-124P