5945-01-230-2168 RELAY,ELECTROMAGNETIC Index 5945-01-230-2170 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-01-230-2169

Federal Supply Class:
5945

National Item Identification Number:
012302169

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
K-D1A-300M59207ESTERLINE TECHNOLOGIES CORPORATION
M83536/15-020M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-8353681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-83536/1581349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-610681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS27400-3596906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MS27400-36X96906MILITARY STANDARDS PROMULGATED BY MILITARY DEPARTMENTS UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE1.446 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
CRITICALITY CODE JUSTIFICATIONFEAT
CUBIC MEASURE2.324 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT1.320 INCHES MAXIMUM
OVERALL LENGTH1.718 INCHES MAXIMUM
OVERALL WIDTH1.025 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY3 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNTRIANGLE SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIAL FEATURESFAILURE RATE LEVEL 0.3 PERCENT
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
WINDING DC RESISTANCE RATING290.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY14 PIN ALL FUNCTIONS
TIME DELAY0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME