5945-01-259-9534 RELAY,ELECTROMAGNETIC Index 5945-01-259-9536 RELAY,ELECTROMAGNETIC

National Stock Number:
5945-01-259-9535

Federal Supply Class:
5945

National Item Identification Number:
012599535

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
402-0524-01095105ROCKWELL COLLINS, INC.
TDH8061-100258657LEACH INTERNATIONAL CORP


Techincal Specification:
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP30.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
NOMINAL OPERATING CURRENT RATING AND TYPE150.0 MILLIAMPERES DC SINGLE WINDING
TERMINAL TYPE AND QUANTITY8 WIRE HOOK ALL FUNCTIONS
TIME DELAY1.00 SECONDS MINIMUM AND
10.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME
DUTY TYPECONTINUOUS
ENVIRONMENTAL PROTECTIONHERMETIC
OVERALL LENGTH1.718 INCHES MAXIMUM
OVERALL WIDTH1.025 INCHES MAXIMUM
OVERALL HEIGHT1.318 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY3 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNTRIANGLE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE1.396 INCHES MINIMUM AND
1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
PURPOSE FOR WHICH DESIGNEDGENERAL
CUBIC MEASURE2.321 CUBIC INCHES
FRAGILITY FACTORMODERATELY RUGGED
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
CASE MATERIALMETAL
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND
28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE10.0 AMPERES AC AND
10.0 AMPERES DC RESISTIVE LOAD
8.0 AMPERES AC AND
8.0 AMPERES DC INDUCTIVE LOAD
2.0 AMPERES AC AND
2.0 AMPERES DC LAMP LOAD
4.0 AMPERES AC AND
4.0 AMPERES DC MOTOR LOAD
ARC QUENCHING METHODAIR
COIL QUANTITY1
WINDING QUANTITY1


Click here to Register for Free 30-day Trial