5925-01-278-7148 CIRCUIT BREAKER Index 5935-01-278-7150 CONNECTOR,PLUG,ELECTRICAL

National Stock Number:
5945-01-278-7149

Federal Supply Class:
5945

National Item Identification Number:
012787149

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
596-7410894-AY-1-2853711NAVAL SEA SYSTEMS COMMAND
B673-4030-AY-1-2896169ELECTRIC BOAT CORPORATION
M6106/27-022P81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M83536/1-024M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M83536/1-024R81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-83536/181349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-8353681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
DUTY TYPECONTINUOUS
ARC QUENCHING METHODAIR
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.062 INCHES MINIMUM AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY
COIL QUANTITY1
CRITICALITY CODE JUSTIFICATIONFEAT
CUBIC MEASURE0.336 CUBIC INCHES
ENVIRONMENTAL PROTECTIONHERMETIC
FEATURES PROVIDEDPOLARIZED
FRAGILITY FACTORMODERATELY RUGGED
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE1.0 AMPERES AC AND 1.0 AMPERES DC LAMP LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE2.0 AMPERES AC AND 1.0 AMPERES DC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE3.0 AMPERES AC AND 3.0 AMPERES DC INDUCTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC AND 5.0 AMPERES DC RESISTIVE LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
OVERALL HEIGHT0.620 INCHES MINIMUM AND 0.640 INCHES MAXIMUM
OVERALL LENGTH1.260 INCHES MINIMUM AND 1.280 INCHES MAXIMUM
OVERALL WIDTH0.390 INCHES MINIMUM AND 0.410 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 SLOTTED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNIN-LINE SINGLE MOUNTING FACILITY
MOUNTING SLOT WIDTH0.133 INCHES NOMINAL SINGLE MOUNTING FACILITY
NOMINAL OPERATING CURRENT RATING AND TYPE65.0 MILLIAMPERES DC SINGLE WINDING
NONPILE-UP MAIN CONTACT ARRANGEMENT2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
PURPOSE FOR WHICH DESIGNEDGENERAL
SPECIAL FEATURESFAILURE RATE LEVEL 0.3 PERCENT
SPECIFICATION/STANDARD DATA81349-MIL-R-6106/27 GOVERNMENT SPECIFICATION
STORAGE TYPEGENERAL PURPOSE WAREHOUSE
WINDING DC RESISTANCE RATING500.0 OHMS NOMINAL SINGLE WINDING
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY8 PIN ALL FUNCTIONS
TEST DATA DOCUMENT81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
TIME DELAY0.004 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME


Click here to Register for Free 30-day Trial