DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
CUBIC MEASURE | 6.037 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | POLARIZED |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC AND 2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES AC AND 4.0 AMPERES DC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES AC AND 8.0 AMPERES DC INDUCTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
OVERALL HEIGHT | 1.720 INCHES MINIMUM AND 1.780 INCHES MAXIMUM |
OVERALL LENGTH | 2.730 INCHES MINIMUM AND 2.780 INCHES MAXIMUM |
OVERALL WIDTH | 1.160 INCHES MINIMUM AND 1.220 INCHES MAXIMUM |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
NOMINAL OPERATING CURRENT RATING AND TYPE | 300.0 MILLIAMPERES DC SINGLE WINDING |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PURPOSE FOR WHICH DESIGNED | GENERAL |
WINDING QUANTITY | 1 |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 8 WIRE HOOK ALL FUNCTIONS |
TIME DELAY | 5.00 SECONDS NOMINAL FIXED OPERATE TIME |
UNTHREADED MOUNTING HOLE DIAMETER | 0.177 INCHES NOMINAL SINGLE MOUNTING FACILITY |