DUTY TYPE | CONTINUOUS |
ARC QUENCHING METHOD | AIR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.412 INCHES MINIMUM AND 1.462 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.990 INCHES MINIMUM AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
CUBIC MEASURE | 2.450 CUBIC INCHES |
ENVIRONMENTAL PROTECTION | HERMETIC |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND 10.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES DC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES DC INDUCTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
OVERALL HEIGHT | 1.010 INCHES MAXIMUM |
OVERALL LENGTH | 1.708 INCHES MAXIMUM |
OVERALL WIDTH | 1.400 INCHES MINIMUM AND 1.420 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PRECIOUS MATERIAL | GOLD |
PRECIOUS MATERIAL AND LOCATION | TERMINALS GOLD |
PURPOSE FOR WHICH DESIGNED | GENERAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
WINDING DC RESISTANCE RATING | 210.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 20 PIN ALL FUNCTIONS |
TIME DELAY | 0.015 SECONDS NOMINAL FIXED OPERATE AND RELEASE TIME |
UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES MINIMUM AND 0.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY |