COIL QUANTITY | 1 |
CUBIC MEASURE | 1.348 CUBIC INCHES |
DUTY TYPE | CONTINUOUS |
ENVIRONMENTAL PROTECTION | HERMETIC |
FRAGILITY FACTOR | MODERATELY RUGGED |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 120.0 AC AND 28.0 DC |
MATERIAL | STEEL CORROSION RESISTING CASE |
MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED STUD SINGLE MOUNTING FACILITY |
NOMINAL THREAD SIZE | 0.099 INCHES SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
OVERALL HEIGHT | 1.281 INCHES MAXIMUM |
OVERALL LENGTH | 1.156 INCHES MAXIMUM |
OVERALL WIDTH | 0.910 INCHES MAXIMUM |
PURPOSE FOR WHICH DESIGNED | GENERAL |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
TERMINAL TYPE AND QUANTITY | 14 TAB, SOLDER LUG ALL FUNCTIONS |
THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
TIME DELAY | 0.006 SECONDS NOMINAL FIXED RELEASE TIME |
TIME DELAY | 0.013 SECONDS NOMINAL FIXED OPERATE TIME |
WINDING DC RESISTANCE RATING | 3.9 KILOHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |