NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 125.0 MILLIAMPERES AC AND |
| 2.0 AMPERES DC RESISTIVE LOAD |
| 500.0 MILLIAMPERES DC INDUCTIVE LOAD |
| 100.0 MILLIAMPERES DC LAMP LOAD |
COIL QUANTITY | 2 |
WINDING QUANTITY | 2 |
WINDING DC RESISTANCE RATING | 37.0 OHMS NOMINAL ALL WINDINGS |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 6.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
TERMINAL TYPE AND QUANTITY | 16 WIRE LEAD ALL FUNCTIONS |
DUTY TYPE | CONTINUOUS |
OVERALL LENGTH | 0.610 INCHES MAXIMUM |
OVERALL WIDTH | 0.610 INCHES MAXIMUM |
OVERALL HEIGHT | 0.320 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
SPECIAL FEATURES | FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES |
TEST DATA DOCUMENT | 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |
SPECIFICATION/STANDARD DATA | 81349-MIL-R-39016/35 GOVERNMENT SPECIFICATION |
CRITICALITY CODE JUSTIFICATION | FEAT |
PURPOSE FOR WHICH DESIGNED | GENERAL |
CUBIC MEASURE | 0.119 CUBIC INCHES |
FRAGILITY FACTOR | MODERATELY RUGGED |
STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
SPEC/STD CONTROLLING DATA | |
MANUFACTURERS CODE | 81349 |
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | MIL-PRF-39016/35 |
DEFINITIVE GOVERNMENT SPEC/STD REFERENCE | M39016/35-001P |