| NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND |
| 28.0 DC |
| MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC AND |
| 10.0 AMPERES DC RESISTIVE LOAD |
| 8.0 AMPERES AC AND |
| 8.0 AMPERES DC INDUCTIVE LOAD |
| 2.0 AMPERES AC AND |
| 2.0 AMPERES DC LAMP LOAD |
| 4.0 AMPERES AC AND |
| 4.0 AMPERES DC MOTOR LOAD |
| ARC QUENCHING METHOD | AIR |
| COIL QUANTITY | 1 |
| WINDING QUANTITY | 1 |
| OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| TERMINAL TYPE AND QUANTITY | 14 PIN ALL FUNCTIONS |
| TIME DELAY | 0.90 SECONDS MINIMUM AND |
| 1.10 SECONDS MAXIMUM FIXED OPERATE TIME |
| 0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
| DUTY TYPE | CONTINUOUS |
| ENVIRONMENTAL PROTECTION | DUSTPROOF |
| OVERALL LENGTH | 1.310 INCHES MAXIMUM |
| OVERALL WIDTH | 1.040 INCHES MAXIMUM |
| OVERALL HEIGHT | 2.070 INCHES MAXIMUM |
| MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| PURPOSE FOR WHICH DESIGNED | GENERAL |
| CUBIC MEASURE | 2.820 CUBIC INCHES |
| FRAGILITY FACTOR | MODERATELY RUGGED |
| STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |