DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.100 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.100 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.1 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.2 AMPERES DC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
OVERALL HEIGHT | 0.398 INCHES MAXIMUM |
OVERALL LENGTH | 0.370 INCHES MAXIMUM |
OVERALL WIDTH | 0.370 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
PILE-UP MAIN CONTACT FORM ARRANGEMENT | 1C |
SPECIAL FEATURES | LOW LEVEL TO 1 AMP, PWB, SPDT RELAY. RATED 12.0 VDC COIL WITH 3% FAILURE RATE. |
SPECIFICATION/STANDARD DATA | 81349-M-39016/07-034L GOVERNMENT SPECIFICATION |
WINDING DC RESISTANCE RATING | 500.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 2 |
TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD ENERGIZING ELEMENT |
TERMINAL TYPE AND QUANTITY | 3 WIRE LEAD CONTACTS |
TEST DATA DOCUMENT | 81349-MIL-PRF-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |