DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.396 INCHES MINIMUM AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
ENVIRONMENTAL PROTECTION | HERMETIC |
FEATURES PROVIDED | POLARIZED AND COIL VOLTAGE SUPPRESSION |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC AND 10.0 AMPERES AC RESISTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC AND 2.0 AMPERES AC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES DC AND 4.0 AMPERES AC MOTOR LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES DC AND 8.0 AMPERES AC INDUCTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
OVERALL HEIGHT | 0.525 INCHES MAXIMUM |
OVERALL LENGTH | 1.010 INCHES MAXIMUM |
OVERALL WIDTH | 1.025 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
SPECIAL FEATURES | RELAYS POLARIZED WITH A PERMANENT MAGNET AND WILL NOT OPERATE OR BE DAM AGED BY REVERSE POLARITY |
WINDING DC RESISTANCE RATING | 320.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 PIN ALL FUNCTIONS |