8430-01-492-1808 BOOTS,COMBAT Index 7610-01-492-1810 MANUAL,VALIDITY INDICATOR PROFIL

National Stock Number:
5945-01-492-1809

Federal Supply Class:
5945

National Item Identification Number:
014921809

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
M39016/53-011L81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
M39016/53-011M81349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-PRF-39016/5381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-3901681349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M
MIL-R-39016/5381349MILITARY SPECIFICATIONS PROMULGATED BY MILITARY DEPARTMENTS/AGENCIES UNDER AUTHORITY OF DEFENSE STANDARDIZATION MANUAL 4120 3-M


Techincal Specification:
NONPILE-UP MAIN CONTACT ARRANGEMENT4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND
28.0 DC
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE2.0 AMPERES DC AND
0.5 AMPERES AC RESISTIVE LOAD
0.5 AMPERES DC INDUCTIVE LOAD
0.10 AMPERES DC LAMP LOAD
COIL QUANTITY1
WINDING QUANTITY1
WINDING DC RESISTANCE RATING720.0 OHMS NOMINAL SINGLE WINDING
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP26.5 VOLTS AC 25 DEG CELSIUS SINGLE WINDING
TERMINAL TYPE AND QUANTITY14 TAB, SOLDER LUG ALL FUNCTIONS
DUTY TYPECONTINUOUS
ENVIRONMENTAL PROTECTIONHERMETIC
OVERALL LENGTH1.062 INCHES MAXIMUM
OVERALL WIDTH0.610 INCHES MAXIMUM
OVERALL HEIGHT0.320 INCHES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
MOUNTING FACILITY PATTERNTRIANGLE SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE0.300 INCHES MINIMUM SINGLE MOUNTING FACILITY
UNTHREADED MOUNTING HOLE DIAMETER0.096 INCHES NOMINAL SINGLE MOUNTING FACILITY
SPECIAL FEATURESFAILURE RATE LEVEL OF 1 PERCENT PER 10,000 CYCLES
TEST DATA DOCUMENT81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.).
SPECIFICATION/STANDARD DATA81349-MIL-R-39016/53-011 GOVERNMENT SPECIFICATION
SPEC/STD CONTROLLING DATA
MANUFACTURERS CODE81349
NON-DEFINITIVE GOVERNMENT SPEC/STD REFERENCEMIL-PRF-39016/53
DEFINITIVE GOVERNMENT SPEC/STD REFERENCEM39016/53-011M


Click here to Register for Free 30-day Trial