5306-01-493-4160 BOLT,SHEAR Index 6150-01-493-4162 CABLE ASSEMBLY,SPECIAL PURPOSE,E

National Stock Number:
5945-01-493-4161

Federal Supply Class:
5945

National Item Identification Number:
014934161

Description:
RELAY,ELECTROMAGNETIC

Detail:
A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; and SWITCH, STEPPING.


Manufacturer Information:
C-21AA74063TE CONNECTIVITY CORPORATION


Techincal Specification:
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE1.0 AMPERES AC LAMP LOAD
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE3.0 AMPERES AC INDUCTIVE LOAD
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE3.0 AMPERES AC RESISTIVE LOAD
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS115.0 AC AND 28.0 DC
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY
COIL QUANTITY1
FREQUENCY IN HERTZ400.0 NOMINAL
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC MOTOR LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE25.0 AMPERES AC RESISTIVE LOAD
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE5.0 AMPERES AC LAMP LOAD
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS208.0 AC
OVERALL HEIGHT3.000 INCHES MAXIMUM
OVERALL LENGTH3.210 INCHES MAXIMUM
OVERALL WIDTH3.210 INCHES MAXIMUM
MOUNTING FACILITY PATTERNRECTANGULAR SINGLE MOUNTING FACILITY
MOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE SINGLE MOUNTING FACILITY
NONPILE-UP MAIN CONTACT ARRANGEMENT3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP18.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
WINDING QUANTITY1
TERMINAL TYPE AND QUANTITY8 THREADED STUD ENERGIZING ELEMENT AND CONTACTS
UNTHREADED MOUNTING HOLE DIAMETER0.176 INCHES MINIMUM AND 0.182 INCHES MAXIMUM SINGLE MOUNTING FACILITY