DUTY TYPE | CONTINUOUS |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.100 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.100 INCHES NOMINAL SINGLE MOUNTING FACILITY |
COIL QUANTITY | 1 |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.1 AMPERES DC LAMP LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 0.2 AMPERES DC INDUCTIVE LOAD |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES DC RESISTIVE LOAD |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
OVERALL HEIGHT | 0.375 INCHES MAXIMUM |
OVERALL LENGTH | 0.375 INCHES MAXIMUM |
OVERALL WIDTH | 0.335 INCHES MAXIMUM |
MOUNTING FACILITY TYPE AND QUANTITY | 1 PRINTED CIRCUIT TERMINAL SINGLE MOUNTING FACILITY |
NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
SPECIAL FEATURES | FAILURE RATE 1.0 PERCENT PER 10,000 OPERATIONS; REVERSE POLARITY ON COILTERMINALS WILL DESTROY DIODE |
SPECIFICATION/STANDARD DATA | 81349-MIL-PRFM-39016/42-043M GOVERNMENT SPECIFICATION |
WINDING DC RESISTANCE RATING | 800.0 OHMS NOMINAL SINGLE WINDING |
WINDING QUANTITY | 1 |
TERMINAL TYPE AND QUANTITY | 8 WIRE LEAD ALL FUNCTIONS |
TEST DATA DOCUMENT | 81349-MIL-PRF-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |